TELENETICS |
Telenetics has designed modems that work in "remote" remote sites with very low failure rates. These devices work where other modems roll over and die. When a service call to a remote site can mean an all day trip these modems are the ideal solution.
12 Volt DC Power Modem
1.2, 2.4, 9.6, 14.4 & 28.8kbps
MIU/PowerPort
|
jump to MIUPowerPort manual .doc file
The MIU/PowerPort is an industrial grade modem that can be powered directly through the RS232 (DB25) data interface port or power jack.
MIU/PowerPort can be powered by delivering +5VDC (regulated) through pin 10 of the DB25. An optional 12VDC version is also available. Alternatively, an external jack allows the MIU/PowerPort to be powered from a wall transformer or other low voltage AC or DC power source.
When not on line, the dial up MIU/PowerPort modems automatically go into a power down mode and consumes only 5m amps while inactive.
The MIU/PowerPort is available with various modulations, including...
...and operates over dial-up and 2 or 4-wire leased lines at full or half duplex as appropriate.
The MIU/PowerPort has a sister product, the MIU/PowerPack, which is powered from an internal, rechargeable Ni-Cad battery. The battery draws its charging current from the DTEs RS232 interface or an optional solar panel. For more information, ask for the MIU/PowerPack brochure and specifications.
The MIU/PowerPort is fully Hayes AT command set compatible with programmable S-registers.
All models will operate in temperatures from -40 to 85oC and are surge protected on the analog line up to 5kV.
jump to other Telenetics pages
Technical Specifications |
MIU/PowerPort 202T xx |
MIU/PowerPort 2.4 |
MIU/PowerPort 9.6 & 9.6L |
MIU/PowerPort 14.4 & 14.4L |
MIU/PowerPort 28.8 |
Modem Line
Speeds: Asynchronous |
0 - 1200bps |
2400, 1200, 300bps |
2400, 1200, 300bps |
14400, 9600, 4800, 2400, 1200, 300bps |
28800, 14400, 9600, 4800, 2400, 1200, 300bps |
DTE Rates above modem line speeds (ie; with data compression) | - |
- |
19200, 9600, 4800bps |
57.6, 38.4, |
115.2, 57.6, |
Protocols | Bell 202 |
V.22bis, V.22 |
V.22bis, V.22 |
V.32bis, V.32 V.22bis, V.22 Bell212A, Bell103 |
V.34, V.32bis, V.32 V.22bis, V.22 |
Dial Up | No |
Yes |
Yes (Model 9.6) |
Yes (Model 14.4) |
Yes |
2 Wire Leased Line | Yes1 |
No |
Yes (Model 9.6L2) |
Yes (Model 14.4L2) |
No |
4 Wire Leased Line | Yes1 |
No |
Yes (Model 9.6L2) |
Yes (Model 14.4L2) |
No |
Compatibility | n/a |
Hayes Extended AT Command Set |
|||
Error
Correction/ Data Compression |
None |
None |
MNP 2, 4, 5 & 10 |
||
Power Requirements | +5 VDC ±5% in through Pin 10 on the DB25 Data Port |
||||
Current Consumption | 128mA @ +5VDC 71mA @ 12VDC |
64mA @ +5VDC 35mA @ 12VDC |
100mA @ +5VDC 56mA @ 12VDC |
219mA @ +5VDC 123mA @ 12VDC |
287mA @ +5VDC 160mA @ 12VDC |
Dial up modems can be factory set to automatically
fall into "Power Down" mode |
|||||
Digital Port | RS232 with DB25 Female Connector |
||||
Analog Port | RJ11 |
||||
Surge
Protection (Analog Port) |
3.75kVac |
5kVac |
5kVac |
3.75kVac |
3.75kVac |
Environment | -40oC to +85oC, 0 to 95% humidity (non-condensing) |
||||
Case Size | 5-3/8" x 4" x 1-3/8" |
||||
Certifications | FCC Part 68 Class A, Industry Canada Certified |
Important notes regarding leased line operation: 1 Bell202T is half or full duplex, suitable for point-to-point and multipoint applications. 2 The standard 9.6L & 14.4L models are 4-wire, full or half duplex, point-to-point only. 2-wire, full duplex, point-to-point available on special order.
ARC ELECTRONICS
301-924-7400 EXT 25 / 301-924-7400 EXT 25