StarComm Modems

V.34, V.32bis, V32, V.22bis, V.22, V23, V.21, BELL 212A,
BELL 103J
, BELL 202T DC power 5-72 VDC or 110 VAC

StarComm Modem for DIAL and 2 or 4 LEASED LINE MODEMS
300, 1,200, 2,400, 9,600, 14,400, 19,200, 28,800, 33,600bps

StarComm Modems are IDEAL FOR USE IN:
Solar powered applications, Battery powered applications,
Traffic monitoring systems, Control systems, Supervisory systems.


StarComm modems are still being made now by Telenetics
and we have most models in stock ready to ship
see stocked part numbers StarComm/Telenetics modems

see stocked part numbers with new 125VDC power
StarComm Security modems

see other Telenetics modems

jump to New Industrial Grade modems
DC power, temp rating -40 to +85C

Low Power Modems
300bps through 33.6Kbps
AC and DC Powered
Solar Power Compatible

Low Speed Modems
300bps through 2,400 bps
AC and DC Powered Dial
2 or 4 wire Lease Line
Solar Power Compatible
 

202S / 202T Modems
2 wire, 4 wire, dial
DC and AC powered

Multiport Security Modems
V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J

Lease Line & Dial
Async or Sync Modems

300bps through 33.6Kbps
AC and DC Powered
* see new universal modem  *
3342E-208-4
 

Security
Modems

V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J.

Cellular modem
industrial rated cell communications
with security 

FAST Connect Modems
Quick Connect” 
Transaction Modem Family

Racks-Cables &
Software

 

Temperature Hardened
1442EH-103-2 modem

 

 Starcomm modem chassis pic.GIF (24415 bytes)                            

jump to DC power connections page
for new part numbers


 

Related Pages

 


STARCOMM PRODUCT LIST


Starcom Low Speed Modems – All low speed models offer an AT compatible command interface and support the following modulation standards: V.22bis, V.22, V.21, Bell 212A and Bell 103J.

2400E-000-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
2400E-030-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 9vac or 9-14vdc
2400E-230-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 5.5-14vdc
2400E-330-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 18-75vdc
2400R-030-2 Rack mount, for 2-wire dial and 2-wire leased circuits.

2400E-030-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 9vac or 9-14vdc
2400E-230-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 5.5-14vdc
2400E-330-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 19-75vdc
2400R-030-4 Rack mount, for 2-wire dial and 2 or 4-wire leased circuits.
2400E-034-2 Stand alone, Quick Connect for dial-up transaction processing. Power: 9vac or 9-14vdc
400R-034-2 Rack mount, Quick Connect for dial-up transaction processing applications.


Starcom 202ST Modems - The following modems offer Bell 202S and 202T compatibility. Custom options are also available for dial operation and onboard protocol support.

202TE-037-4 Stand alone, for 2 or 4-wire leased circuits. Power: 9vac or 9-14vdc
202TE-237-4 Stand alone, for 2 or 4-wire leased circuits. Power: 5.5-14vdc
202TE-337-4 Stand alone, for 2 or 4-wire leased circuits. Power: 18-75vdc
202TR-037-4 Rack mount, for 2 or 4-wire leased circuits.


 StarComm  modem V.32bis (14.4kbps)  – All models offer an AT compatible command interface and support the following modulation standards: V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J. The following modulation standards are supported for fax: V.33, V.29 and V.27. Both synchronous and asynchronous DTE are supported.

1442E-003-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 9vac or 9-14vdc
1442E-203-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 5.5-14vdc
1442E-303-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 18-75vdc
1442R-003-2 Rack mount, for 2-wire dial and 2-wire leased circuits.

1442E-003-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 9vac or 9-14vdc
1442E-203-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 5.5-14vdc
1442E-303-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 18-75vdc
1442R-003-4 Rack mount, for 2-wire dial and 2 or 4-wire leased circuits.


StarCom modem V.34 (33.6kbps)  – All models offer an AT compatible command interface and support the following modulation standards: V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J. The following modulation standards are supported for fax: V.33, V.29 and V.27. Both synchronous and asynchronous DTE are supported.

3342E-003-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 9vac or 9-14vdc
3342E-203-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 5.5-14vdc
3342E-303-2 Stand alone, for 2-wire dial and 2-wire leased circuits. Power: 18-75vdc
3342R-003-2 Rack mount, for 2-wire dial and 2-wire leased circuits.
3342R-006-2 Rack mount with network management, for 2-wire dial and 2-wire leased circuits.

3342E-003-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 9vac or 9-14vdc
3342E-203-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 5.5-14vdc
3342E-303-4 Stand alone, for 2-wire dial and 2 or 4-wire leased circuits. Power: 18-75vdc
3342R-003-4 Rack mount, for 2-wire dial and 2 or 4-wire leased circuits.


StarComm modem 1442L and 3342L Low Power Standby Modems – All models offer an AT compatible command interface and support the following modulation standards: V.34(3342 only), V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J. These models are designed to enter a low power standby state when there is no activity. Standby current is approximately 5ma.

1442E-008-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
1442E-208-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
1442E-308-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc
3342E-008-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
3342E-208-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
3342E-308-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc


Starcom Security Modems – All models offer an AT compatible command interface and support the following modulation standards: V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J. Models are available with password protection, caller ID protection and audit trail capabilities with precision time keeping. All models capable of remote configuration and management.

The following models feature password protection with an on board security database holding a maximum of 50 passwords:

3342E-001-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
3342E-201-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
3342E-301-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc
3342R-001-2 Rack mount, for 2-wire dial circuits.

The following models feature password protection, Additional features include Caller ID protection, time keeping and audit trail. Enhanced On-board security database holds 400 passwords/Caller ID keys and 220 audit trail records:

3342E-004-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
3342E-204-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
3342E-304-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc
3342R-004-2 Rack mount, for 2-wire dial circuits.


StarComm CC-2016-XX 16 Slot Racks – All racks provide mounting and power for 16 modem cards. Power supply options and network management options must be specified when ordering.

CC-2016-01 Includes AC supply for operation on 115vac
CC-2016-02 Includes DC supply for operation on 36-75vdc
CC-2016-03 Includes AC supply for operation on 230vac
CC-2016-04 Includes AC supply for operation on 115vac and network management support.
CC-2016-05 Includes DC supply for operation on 36-75vdc and network management support.
CC-2016-06 Includes AC supply for operation on 230vac and network management support.

SOFTWARE

01-9001-001    NETWORK MANAGEMENT SOFTWARE – Manages the operation of properly

equipped CC-2016 racks configured with 3342R-006-2 modems.

01-9002-001 DEVICE MANAGEMENT SOFTWARE – For management and configuration of all


RACKS - The CC-2016-XX Series of 16 Slot Rack Mount Enclosures
These enclosures provide 16 modem slots in a standard 19 inch form factor which is 5 inches high and 6.5 inches in depth. The standard power system auto ranges from 85 to 265VAC with a frequency range of  27 - 440hz. An optional DC supply is also available for installations requiring operation on 36 - 75VDC. All rack configurations are designed for operation from -20C to +70C and offer a mean time between failure (MTBF) of 200,000 hours (22.8) years.

BRACKET - 19 Inch Rack Mount Bracket For All Stand Alone Models
This bracket provides mounting for three 5"x 5"stand alone modems or two 5" by 7" multi-port modems with a standard 19 inch rack.

BRACKET - 9 Inch Wall Mount Bracket For All Stand Alone Models
This wall mount bracket may be attached to all 5" x 5" or 5" x 7" stand alone models.

CABLE - Power Pig Tall For All Stand Alone Models
Three foot, two conductor power pig tail with molded 12mm barrel connector.

CABLE - RJ-SO to DO-2S RS-232 Cable For Multi-Port Models
Two foot RJ-50 male to DB-25 female allows standard DB-25 modem cables to be connected to multi-port modems.

CABLE HARNESSES - For CC-2016-XX Rack Mount Enclosures
These octopus harnesses provide multiple RJ-11 connections to a standard 50 pin teleco connector. The are available in the following configurations:

- Sixteen 2 wire RJ-11 connections to one 50 pin male teleco connector.
- Sixteen 2 wire RJ-11 connections to one 50 pin female teleco connector.
- Eight 4 wire RJ-12 connections to one 50 pin male teleco connector.
- Eight 4 wire RJ-12 connections to one 50 pin female teleco connector.

SOFTWARE - Network Management For CC-2016-Y.X Installations

This software manages the operation of CC-2016-XX racks equipped with the network management option and 3342R-006-2 modems. Network Management software provides screens for configuring and monitoring modems and associated telephone circuits, Real time alerts and reports may be configured to meet the requirements of a specific installation. This software operates on DOS and Windows 3.11.

SOFTWARE - Device Management For All Security and Multi-Port Models

This software provides centralized management of the password, caller ID and audit trail features of all standard security modems and mufti-port modems. Device Management will operate on Windows 95, 98 and NT.


Related Pages


For more information, please contact:

ARC ELECTRONICS
jump to ... Home Page

Phone us at 301-924-7400 EXT 25

e-mail Sales at arc@arcelect.com