GENERAL |
Data Rate: |
1.544M bps |
Operating Modes: |
Line Codes: AMI/B8ZS. Framing: D4/ESF (ATT or ANSI) |
Standard Features: |
Local and remote test with internal pattern generator. Front panel LED
display aids in testing, monitoring and trouble shooting. Full performance monitoring per
ANSI and Bellcore requirements, including 24 hour network with error second information.
All reports available via command port. |
|
|
CUSTOMER INTERFACE |
Connectors: |
One V.35 for DTE interface. |
One DB-25 for RS-530 for DTE interface. |
One DB-25 for command port. (Supports RS-232 PC or terminal) |
Speed: |
1.544Mbps |
Mode: |
Sychronous |
PHYSICAL |
Size: |
Height..............2.5 In. |
Width...............8.0 In. |
Depth...............6.25 In. |
Power: |
117 VAC +/- 10%, 60 HZ. 5 watts |
Environment: |
0 to 50 C, up to 95% humidity |
Rack Mount: |
Fits in current BAT Rack |
LINE INTERFACE |
Line Interface: |
Standard registered jack on rear panel. |
Equalization: |
Fully Automatic and adaptive, no need for user adjustments. |
Line Requirements: |
Digital service at T-1 speed. |
GENERAL |
Data Rate: |
T-1 or fractional T-1 speeds |
Operating Modes: |
Line Codes: AMI/B8ZS. |
Framing: D4/ESF (ATT or ANSI) |
Standard Features: |
Local and Remote test with internal pattern generator |
Front panel LED display aids in testing, monitoring, and trouble shooting. |
Full performance monitoring per ANSI and Bellcore requirements including 24 hour
network error second information. |
All reports available via command port. |
CUSTOMER INTERFACE |
Connectors: |
One V.35 for DTE interface |
One DB.25 for RS-530 for DTE interface |
One DB-25 for command port. (Supports RS-232 PC or terminal) |
Speed: |
Nx56 or Nx64Kbps N=1 to 24. Any selection of DSO's ok. |
Mode: |
Synchronous |
PHYSICAL |
Size: |
Height..............2.5 In. |
Width...............8.0 In. |
Depth...............6.25 In. |
Power: |
117 VAC +/- 10%, 60HZ . 5 watts |
Environment: |
0 to 50 C, up to 95% humidity |
Rack Mount: |
Fits in current BAT Rack |
LINE INTERFACE |
Line Interface: |
Standard registered jack on rear panel. |
Equalization: |
Fully automatic and adaptive, no need for user adjustments. |
Line Requirements: |
Digital service at T-1 or fractional T-1 speeds. |
GENERAL |
Data Rate: |
56,000 BPS |
Operating Modes: |
Dedicated Digital Service, for point to point operation. |
The product may also be used as a Limited Distance Modem. |
Standard Features: |
IN Service LED, internal timing, permanent RTS (user option). |
Non-volatile parameter storage. Dual interfaces. |
Internal pattern generator. Proven design. |
Test Features: |
Ten front panel status and test indicators. Front panel push button
selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop |
Responds to Bell defined loop backs. Internal pattern generator. |
AC Power: |
117 VAC +/- 10%, 60Hz, 12w. |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height.................2.5 in. |
Width.................8.0 in. |
Depth.................6.25 in. |
CUSTOMER INTERFACE |
Connectors: |
One V.35 and one DB-25 connector. |
Configuration: |
Speed.........................56.0K |
Interface......................V.35/ RS-232 |
Sync............................YES |
Signals are present at both connectors |
Data Format: |
Synchronous |
LINE INTERFACE |
Line Interface: |
Standard registered RJ-48s jack on rear panel. |
RX Levels: |
Supports attenuation of greater than 48db. (14 db better than telco
specs) |
Equalization: |
Fully automatic and adaptive, no need for user adjustments. |
Line Requirements: |
Digital Service at 56K. |
GENERAL |
Data Rate: |
56K, 19.2K, 9.6K. |
Rate Selection: |
Auto Adaptive |
Operating Modes: |
8 wire termination of Dataphone Digital Service (DDS) in point to point
or multi-point applications. |
May also be used as Limited Distance Modem in point to point
applications. |
Standard Features: |
IN Service LED, internal timing, DDS slave timing, permanent RTS, (user
option). |
Auto Adaptive rate selection. |
Test Features: |
Ten front panel status and test indicators. Front panel push button
selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop |
Responds to Bell defined CSU and DSU loop backs from the Central
Office. |
Internal pattern generator |
Front panel multi-color LED displays current line rate. |
AC/DC Power: |
117 VAC +/- 10%, 60 Hz, 12w. & 12 - 24 - 48
volt DC power |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height..............2.50 In. |
Width...............8.00 In. |
Depth...............6.25 In. |
CUSTOMER INTERFACE |
Interface: |
V.35 and RS-232 with both connectors and interface circuits. |
Data Format: |
Any Synchronous Format |
Asynchronous format: supports 10/11 bit ASCII |
LINE INTERFACE |
Interface: |
8 wire termination on rear panel RJ-48s. |
Modulation: |
Bipolar return to zero |
RX levels: |
Supports at least 40 db attraction (exceeds Telco requirements by 6 db) |
Equalization: |
Automatic, no user adjustment needed |
GENERAL |
Line Rate: |
56,000 bps |
Operating Modes: |
Switched Digital Service (SDS) in
point-to-point applications. |
Dedicated point-to-point or multi-point
applications. |
Standard Features: |
IN Service LED, internal timing, permanent RTS
(user option) |
Test Features: |
Ten front panel status and test indicators.
Front panel push button selects the following test modes: Self Test, Digital Loop, Local
Loop, Remote Loop. |
Responds to Bell defined loop backs from the
Central Office. |
Internal pattern generator. |
AC Power: |
117 VAC +/- 10%, 60Hz, 12w. |
Environment: |
0 to 50 C, up to 95% humidity. |
CUSTOMER INTERFACE |
Connectors: |
One V.35 and two DB-25 connectors. |
Configuration: |
Speed |
Interface |
Sync |
Async |
|
57.6K |
V.35/ RS-232 |
NO |
YES |
|
56.0K |
V.35/ RS-232 |
YES |
YES |
|
38.4K |
V.35/ RS-232 |
YES |
YES |
|
19.4K |
V.35/ RS-232 |
YES |
YES |
|
9.6K |
V.35/ RS-232 |
YES |
YES |
|
4.8K |
V.35/ RS-232 |
YES |
YES |
|
2.4K |
V.35/ RS-232 |
YES |
YES |
|
1.2K |
V.35/ RS-232 |
YES |
YES |
|
Signals are present at both connectors at all
speeds |
Data Format: |
Synchronous or Asynchronous |
Configuration
Commands: |
User may configure and dial the DUAL-1 using
"standard command set". |
Parameters can be remotely elected and set on
dial or dedicated lines. |
Dial Method: |
"Standard" commands via data port or
auxiliary DB-25 connector provided. |
Optional RS-366 dialing via auxiliary DB-25
connector. |
Parameter Storage: |
Non-volatile. |
Line Interface: |
Standard Registered RJ-48s jack on rear panel. |
RX Levels: |
Supports attenuation of greater than 44db. (10
db better than telco specs) |
Equalization: |
Fully automatic and adaptive, no need for user
adjustments. |
Line Requirements: |
Switched 4 wire digital service or dedicated 4
wire digital service. |
GENERAL |
Line Rate: |
56,000 bps |
Operating Modes: |
Dataphone Digital Service (DDS) in point to point or
multi-point applications. |
May also be used as Limited Distance Modem in point to
point applications. |
Standard Features: |
IN Service LED, internal timing, DDS slave timing,
permanent RTS (user option). |
Test Features: |
Ten front panel status and test indicators. Front panel
push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote
Loop. |
Responds to Bell defined CSU and DSU loop backs from the
Central Office. |
Internal pattern generator. |
AC Power: |
117 VAC +/- 10%, 60Hz, 12w. |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height..................2.50 In. |
Width...................8.00 In. |
Depth...................6.25 In. |
CUSTOMER INTERFACE |
Connectors: |
Both V.35 and RS-232 connectors provided. |
Configuration: |
Speed |
Interface |
Sync |
Async |
|
56.0K |
V.35 |
YES |
NO |
|
38.4K |
RS-232 |
YES |
YES |
|
19.2K |
RS-232 |
YES |
YES |
|
9.6K |
RS-232 |
YES |
YES |
|
4.8K |
RS-232 |
YES |
YES |
|
2.4K |
RS-232 |
YES |
YES |
|
1.2K |
RS-232 |
YES |
YES |
|
Signals are present at both connectors regardless of data
rate. |
Data Format: |
Synchronous or Asynchronous (7/8data bits one stop bit) |
LINE INTERFACE |
Interface: |
Standard registered RJ-48s jack on the rear panel. |
Modulation: |
Bipolar return to zero. |
Impedance: |
135 ohm +/- 10% |
TX level (135ohm load): |
56,000....1.4v peak |
RX levels: |
Supports at least 40 db attenuation (exceeds Telco
requirements by 6 db) |
Equalization: |
Automatic, no user adjustment needed. |
GENERAL |
Line Rate: |
56,000 bps |
Operating Modes: |
Dataphone Digital Service (DDS in point to point or
multi-point applications. |
May also be used as a Limited Distance Modem in point to
point applications |
Test Features: |
Ten front panel status and test indicators. Front panel
push button selects the following modes: Self Test, Digital Loop, Local Loop, Remote Loop.
|
Responds to Bell defined CSU and DSU loop backs from the
Central Office. |
Internal pattern generator. |
AC Power: |
117 VAC +/- 10%, 60 Hz, 12w. |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height......2.50 In. . |
Width.......8.00 In. |
|
|
Depth.......6.25 In. |
|
|
CUSTOMER INTERFACE |
Connectors: |
One V.35 and Two RS-232 connectors provided. |
Configurations: |
MODE 1 |
CHANNEL 1 |
CHANNEL 2 (not used in MODE 1) |
Speed |
Interface |
Sync |
Async |
Speed |
Interface |
Sync |
Async |
56.0K |
V.35 |
YES |
NO |
N/A |
N/A |
N/A |
N/A |
MODE 2 |
CHANNEL 1 |
CHANNEL 2 |
Speed |
Interface |
Sync |
Async |
Speed |
Interface |
Sync |
Async |
38.4K |
RS-232 |
YES |
YES |
9.6K |
RS-232 |
YES |
YES |
19.2K |
RS-232 |
YES |
YES |
4.8K |
RS-232 |
YES |
YES |
9.6K |
RS-232 |
YES |
YES |
2.4K |
RS-232 |
YES |
YES |
4.8K |
RS-232 |
YES |
YES |
1.2K |
RS-232 |
YES |
YES |
MODE 3 |
CHANNEL 1 |
CHANNEL 2 |
Speed |
Interface |
Sync |
Async |
Speed |
Interface |
Sync |
Async |
19.2K |
RS-232 |
YES |
YES |
19.2K |
RS-232 |
YES |
YES |
9.6K |
RS-232 |
YES |
YES |
9.6K |
RS-232 |
YES |
YES |
4.8K |
RS-232 |
YES |
YES |
4.8K |
RS-232 |
YES |
YES |
2.4K |
RS-232 |
YES |
YES |
2.4K |
RS-232 |
YES |
YES |
Channel 2 speeds are independent of Channel 1 speed
settings in modes 2 and 3 |
LINE INTERFACE |
Interface: |
Standard registered RJ-48s jack on the rear panel. |
Modulation: |
Bipolar return to zero. |
Impedance: |
135 ohm +/- 10%. |
TX Level (135 ohm load): |
56,000 bps.....1.4v peak. |
RX Levels: |
Supports at least 40 db attenuation (exceeds Telco
requirements by 6 db) |
Equalization: |
Automatic, no user adjustment needed. |
GENERAL |
Line Rate: |
56,000 bps |
Operating Modes: |
Dataphone Digital Service (DDS) in point to point
applications |
May also be used as Limited Distance Modem. |
Test Features: |
Nine front panel status and test indicators. Front panel
push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote
Loop. |
Supports CSU and DSU loop from the Central Office |
Internal pattern generator. |
AC Power: |
117 VAC +/- 10%, 60 Hz, 12w. |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height 2.50 In |
Width 8.00 In |
Depth 6.25 In |
CUSTOMER INTERFACE: |
Connectors: |
Four RS-232 connectors provided. |
Modes: |
MODE 1 |
|
CHANNEL |
CHANNEL 2 |
CHANNEL 3 |
CHANNEL 4 |
|
Speed |
Speed |
Speed |
Speed |
|
38.4K |
9.6K |
Not Usable |
Not Usable |
MODE 2 |
|
CHANNEL 1 |
CHANNEL 2 |
CHANNEL 3 |
CHANNEL 4 |
|
Speed |
Speed |
Speed |
Speed |
|
19.2K |
19.K |
9.6K |
Not Usable |
MODE 3 |
|
CHANNEL 1 |
CHANNEL 2 |
CHANNEL 3 |
CHANNEL 4 |
|
Speed |
Speed |
Speed |
Speed |
|
19.2K |
9.6K |
9.6K |
9.6K |
MODE 4 |
|
CHANNEL 1 |
CHANNEL 2 |
CHANNEL 3 |
CHANNEL 4 |
|
Speed |
Speed |
Speed |
Speed |
|
9.6K |
9.6K |
9.6K |
9.6K |
ALL CHANNELS CAN RUN SYNC OR ASYNC |
LINE INTERFACE |
Interface: |
Standard registered RJ-48s jack on the rear panel. |
RX Levels: |
Supports at least 40 db attenuation (exceeds Telco
requirements by 6 db). |
Equalization: |
Automatic, no user adjustment needed. |
GENERAL |
Line Rate: |
56K, 19.2K, 9.6K auto adaptive |
Operating Modes: |
Dataphone Digital Service (DDS) in point to point or
multi-point applications. |
May also be used as Limited Distance Modem. |
Standard Features: |
Slave and master timing. |
Async operation. |
Integral diagnostics. |
Adaptable terminal side rates. |
Both RS-232 and V.35 connectors and interfaces provided. |
Test Features: |
Ten front panel status and test indicators. Front panel push
button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop.
|
Responds to Bell defined CSU and DSU loop backs from the
Central Office. |
Internal test pattern generator. |
AC Power: |
117 VAC +/- 10%, 60 Hz, 12w |
Environment: |
0 to 50 C, up to 95% humidity. |
Physical: |
Height..............2.50 In. |
Width...............8.00 In. |
Depth...............6.25 In. |
CUSTOMER INTERFACE |
Connectors: |
Both V.35 and RS-232 connectors and interfaces provided. |
Operating Modes: |
Mode 1: |
Telco Line Speed 56K |
Terminal Config.: |
Speed |
Interface |
Sync |
Async |
|
|
56.0K |
V.35 |
YES |
NO |
|
|
38.4K |
RS-232 |
YES |
YES |
|
|
19.2K |
RS-232 |
YES |
YES |
|
|
9.6K |
RS-232 |
YES |
YES |
|
|
4.8K |
RS-232 |
YES |
YES |
|
|
2.4K |
RS-232 |
YES |
YES |
|
|
1.2K |
RS-232 |
YES |
YES |
|
MODE 2: |
Telco Line Speed 19.2K |
Terminal Config.: |
19.2K |
RS-232 |
YES |
YES |
|
MODE 3 |
Telco Line Speed 9.6K |
Terminal Config.: |
9.6K |
RS-232 |
YES |
YES |
|
Data Format: |
Synchronous or Asynchronous (7/8 data bits one stop bit) |
LINE INTERFACE |
Interface: |
Standard registered RJ-48s jack on the rear panel. |
RX Levels: |
Supports 40 db attenuation (exceeds requirements by 6 db). |
Equalization: |
Automatic, no user adjustment needed. |
CUSTOMER |
DATA INTERFACES: |
Both V.35 and RS-232 connectors and interfaces are
provided. |
VOICE INTERFACES: |
Three separate voice interfaces and jacks are provided. |
The SPEAK EZ-2 can accommodate a telephone, PBX tie
trunk, or a PBX extension line. |
All of the necessary couplers are provided and are internal
to the device.
|
FAX SIGNALING: |
The SPEAK EZ-2 supports FAX through its voice port. |
SIGNALING: |
Audible remote ringing and dial tone and touch tone
propagation. Integral ringer provided. |
CONFIGURATIONS: |
VOICE SPEED |
DATA SPEED |
16K |
38.4K OR 19.2K |
32K |
19.2K OR 9.6K |
REAR PANEL: |
The rear panel contains the following: |
3] Voice Jacks |
1] V.35 Connector |
1] RS-232 Connector |
1] DIP to set options |
1] Telephone line connection |
1] Power connection |
CSU / DSU |
LINE RATE: |
56K BPS |
LINE INTERFACE: |
Standard DDS service. Supports up to 48db of attenuaton. |
FEATURES: |
Internal external timing, permanent RTS. |
TEST FEATURES: |
Supports CSU/DSU loop as well as standard BAT remote
test features. |
Front panel selector enables the test capabilities
including local loop and digital loop. |
Internal test pattern generator supplied. |
GENERAL |
AC POWER: |
117 VAC +/- 10%, 60 HZ, 30 WATTS |
POWER ISOLATION: |
Terminal equipment interfaces operate from their own
isolated power. This eliminates telephone to computer system ground loops. |
ENVIRONMENT: |
0 to 50 C, up to 95% humidity. |
PACKAGING: |
Table top enclosure, with rack mount capability. |