BAT Electronics

T1 Factional T1 56Kbps 9.6 to 56Kbps CSU/DSU Switched Digital Service, 2 port 56Kbps, 4 port 56Kbps CSU/DSU, multi-rate & voice & data port 56Kbps CSU/DSU


Now available with a power input option of 12, 24 or 48 VDC

jump to Related CSU/DSU pages

 


 Standard Product Specifications

EZ-T1-T1 CSU/DSU | EZ-FT1-Factional T1 CSU/DSU | EZ-56K-56Kbps CSU/DSU | SU5696-9.6 to 56Kbps CSU/DSU| DUAL-1 Switched Digital Service| VRT-1-56Kbps CSU/DSU VRT-2 2 port 56Kbps CSU/DSU| VRT-4 4 port 56Kbps CSU/DSU| VRL-1 multi-rate CSU/DSU| SPEAK EZ-2-voice & data port 56Kbps CSU/DSU

                                 jump to Rack - Chassis page


BAT EZ-T1 Specifications

GENERAL
Data Rate: 1.544M bps
Operating Modes: Line Codes: AMI/B8ZS. Framing: D4/ESF (ATT or ANSI)
Standard Features: Local and remote test with internal pattern generator. Front panel LED display aids in testing, monitoring and trouble shooting. Full performance monitoring per ANSI and Bellcore requirements, including 24 hour network with error second information. All reports available via command port.
CUSTOMER INTERFACE
Connectors: One V.35 for DTE interface.
One DB-25 for RS-530 for DTE interface.
One DB-25 for command port. (Supports RS-232 PC or terminal)
Speed: 1.544Mbps
Mode: Sychronous
PHYSICAL
Size: Height..............2.5 In.
Width...............8.0 In.
Depth...............6.25 In.
Power: 117 VAC +/- 10%, 60 HZ. 5 watts
Environment: 0 to 50 C, up to 95% humidity
Rack Mount: Fits in current BAT Rack
LINE INTERFACE
Line Interface: Standard registered jack on rear panel.
Equalization: Fully Automatic and adaptive, no need for user adjustments.
Line Requirements: Digital service at T-1 speed.

 


BAT EZ-FT1 Specifications

GENERAL
Data Rate: T-1 or fractional T-1 speeds
Operating Modes: Line Codes: AMI/B8ZS.
Framing: D4/ESF (ATT or ANSI)
Standard Features: Local and Remote test with internal pattern generator
Front panel LED display aids in testing, monitoring, and trouble shooting.
Full performance monitoring per ANSI and Bellcore requirements including 24 hour network error second information.
All reports available via command port.
CUSTOMER INTERFACE
Connectors: One V.35 for DTE interface
One DB.25 for RS-530 for DTE interface
One DB-25 for command port. (Supports RS-232 PC or terminal)
Speed: Nx56 or Nx64Kbps N=1 to 24. Any selection of DSO's ok.
Mode: Synchronous
PHYSICAL
Size: Height..............2.5 In.
Width...............8.0 In.
Depth...............6.25 In.
Power: 117 VAC +/- 10%, 60HZ . 5 watts
Environment: 0 to 50 C, up to 95% humidity
Rack Mount: Fits in current BAT Rack
LINE INTERFACE
Line Interface: Standard registered jack on rear panel.
Equalization: Fully automatic and adaptive, no need for user adjustments.
Line Requirements: Digital service at T-1 or fractional T-1 speeds.

BAT EZ-56K Specifications

GENERAL
Data Rate: 56,000 BPS
Operating Modes: Dedicated Digital Service, for point to point operation.
The product may also be used as a Limited Distance Modem.
Standard Features: IN Service LED, internal timing, permanent RTS (user option).
Non-volatile parameter storage. Dual interfaces.
Internal pattern generator. Proven design.
Test Features: Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop
Responds to Bell defined loop backs. Internal pattern generator.
AC Power: 117 VAC +/- 10%, 60Hz, 12w.
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height.................2.5 in.
Width.................8.0 in.
Depth.................6.25 in.
CUSTOMER INTERFACE
Connectors: One V.35 and one DB-25 connector.
Configuration: Speed.........................56.0K
Interface......................V.35/ RS-232
Sync............................YES
Signals are present at both connectors
Data Format: Synchronous
LINE INTERFACE
Line Interface: Standard registered RJ-48s jack on rear panel.
RX Levels: Supports attenuation of greater than 48db. (14 db better than telco specs)
Equalization: Fully automatic and adaptive, no need for user adjustments.
Line Requirements: Digital Service at 56K.

BAT SU5696 Specifications

GENERAL
Data Rate: 56K, 19.2K, 9.6K.
Rate Selection: Auto Adaptive
Operating Modes: 8 wire termination of Dataphone Digital Service (DDS) in point to point or multi-point applications.
May also be used as Limited Distance Modem in point to point applications.
Standard Features: IN Service LED, internal timing, DDS slave timing, permanent RTS, (user option).
Auto Adaptive rate selection.
Test Features: Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop
Responds to Bell defined CSU and DSU loop backs from the Central Office.
Internal pattern generator
Front panel multi-color LED displays current line rate.
AC/DC Power: 117 VAC +/- 10%, 60 Hz, 12w. & 12 - 24 - 48 volt DC power
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height..............2.50 In.
Width...............8.00 In.
Depth...............6.25 In.
CUSTOMER INTERFACE
Interface: V.35 and RS-232 with both connectors and interface circuits.
Data Format: Any Synchronous Format
Asynchronous format: supports 10/11 bit ASCII
LINE INTERFACE
Interface: 8 wire termination on rear panel RJ-48s.
Modulation: Bipolar return to zero
RX levels: Supports at least 40 db attraction (exceeds Telco requirements by 6 db)
Equalization: Automatic, no user adjustment needed

 


BAT DUAL-1 Specifications

GENERAL
Line Rate: 56,000 bps
Operating Modes: Switched Digital Service (SDS) in point-to-point applications.
Dedicated point-to-point or multi-point applications.
Standard Features: IN Service LED, internal timing, permanent RTS (user option)
Test Features: Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop.
Responds to Bell defined loop backs from the Central Office.
Internal pattern generator.
AC Power: 117 VAC +/- 10%, 60Hz, 12w.
Environment: 0 to 50 C, up to 95% humidity.
CUSTOMER INTERFACE
Connectors: One V.35 and two DB-25 connectors.
Configuration: Speed Interface Sync Async
57.6K V.35/ RS-232 NO YES
56.0K V.35/ RS-232 YES YES
38.4K V.35/ RS-232 YES YES
19.4K V.35/ RS-232 YES YES
9.6K V.35/ RS-232 YES YES
4.8K V.35/ RS-232 YES YES
2.4K V.35/ RS-232 YES YES
1.2K V.35/ RS-232 YES YES
Signals are present at both connectors at all speeds
Data Format: Synchronous or Asynchronous
Configuration Commands: User may configure and dial the DUAL-1 using "standard command set".
Parameters can be remotely elected and set on dial or dedicated lines.
Dial Method: "Standard" commands via data port or auxiliary DB-25 connector provided.
Optional RS-366 dialing via auxiliary DB-25 connector.
Parameter Storage: Non-volatile.
Line Interface: Standard Registered RJ-48s jack on rear panel.
RX Levels: Supports attenuation of greater than 44db. (10 db better than telco specs)
Equalization: Fully automatic and adaptive, no need for user adjustments.
Line Requirements: Switched 4 wire digital service or dedicated 4 wire digital service.

BAT VRT-1 Specifications

GENERAL
Line Rate: 56,000 bps
Operating Modes: Dataphone Digital Service (DDS) in point to point or multi-point applications.
May also be used as Limited Distance Modem in point to point applications.
Standard Features: IN Service LED, internal timing, DDS slave timing, permanent RTS (user option).
Test Features: Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop.
Responds to Bell defined CSU and DSU loop backs from the Central Office.
Internal pattern generator.
AC Power: 117 VAC +/- 10%, 60Hz, 12w.
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height..................2.50 In.
Width...................8.00 In.
Depth...................6.25 In.
CUSTOMER INTERFACE
Connectors: Both V.35 and RS-232 connectors provided.
Configuration: Speed Interface Sync Async
56.0K V.35 YES NO
38.4K RS-232 YES YES
19.2K RS-232 YES YES
9.6K RS-232 YES YES
4.8K RS-232 YES YES
2.4K RS-232 YES YES
1.2K RS-232 YES YES
Signals are present at both connectors regardless of data rate.
Data Format: Synchronous or Asynchronous (7/8data bits one stop bit)
LINE INTERFACE
Interface: Standard registered RJ-48s jack on the rear panel.
Modulation: Bipolar return to zero.
Impedance: 135 ohm +/- 10%
TX level (135ohm load): 56,000....1.4v peak
RX levels: Supports at least 40 db attenuation (exceeds Telco requirements by 6 db)
Equalization: Automatic, no user adjustment needed.

BAT VRT-2 Specifications

GENERAL
Line Rate: 56,000 bps
Operating Modes: Dataphone Digital Service (DDS in point to point or multi-point applications.
May also be used as a Limited Distance Modem in point to point applications
Test Features: Ten front panel status and test indicators. Front panel push button selects the following modes: Self Test, Digital Loop, Local Loop, Remote Loop.
Responds to Bell defined CSU and DSU loop backs from the Central Office.
Internal pattern generator.
AC Power: 117 VAC +/- 10%, 60 Hz, 12w.
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height......2.50 In. .
Width.......8.00 In.
Depth.......6.25 In.
CUSTOMER INTERFACE
Connectors: One V.35 and Two RS-232 connectors provided.
Configurations:
MODE 1
CHANNEL 1 CHANNEL 2 (not used in MODE 1)
Speed Interface Sync Async Speed Interface Sync Async
56.0K V.35 YES NO N/A N/A N/A N/A
MODE 2
CHANNEL 1 CHANNEL 2
Speed Interface Sync Async Speed Interface Sync Async
38.4K RS-232 YES YES 9.6K RS-232 YES YES
19.2K RS-232 YES YES 4.8K RS-232 YES YES
9.6K RS-232 YES YES 2.4K RS-232 YES YES
4.8K RS-232 YES YES 1.2K RS-232 YES YES
MODE 3
CHANNEL 1 CHANNEL 2
Speed Interface Sync Async Speed Interface Sync Async
19.2K RS-232 YES YES 19.2K RS-232 YES YES
9.6K RS-232 YES YES 9.6K RS-232 YES YES
4.8K RS-232 YES YES 4.8K RS-232 YES YES
2.4K RS-232 YES YES 2.4K RS-232 YES YES
Channel 2 speeds are independent of Channel 1 speed settings in modes 2 and 3
LINE INTERFACE
Interface: Standard registered RJ-48s jack on the rear panel.
Modulation: Bipolar return to zero.
Impedance: 135 ohm +/- 10%.
TX Level (135 ohm load): 56,000 bps.....1.4v peak.
RX Levels: Supports at least 40 db attenuation (exceeds Telco requirements by 6 db)
Equalization: Automatic, no user adjustment needed.

BAT VRT-4 Specifications

GENERAL
Line Rate: 56,000 bps
Operating Modes: Dataphone Digital Service (DDS) in point to point applications
May also be used as Limited Distance Modem.
Test Features: Nine front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop.
Supports CSU and DSU loop from the Central Office
Internal pattern generator.
AC Power: 117 VAC +/- 10%, 60 Hz, 12w.
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height 2.50 In
Width 8.00 In
Depth 6.25 In
CUSTOMER INTERFACE:
Connectors: Four RS-232 connectors provided.
Modes:
MODE 1
CHANNEL CHANNEL 2 CHANNEL 3 CHANNEL 4
Speed Speed Speed Speed
38.4K 9.6K Not Usable Not Usable
MODE 2
CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4
Speed Speed Speed Speed
19.2K 19.K 9.6K Not Usable
MODE 3
CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4
Speed Speed Speed Speed
19.2K 9.6K 9.6K 9.6K
MODE 4
CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4
Speed Speed Speed Speed
9.6K 9.6K 9.6K 9.6K
ALL CHANNELS CAN RUN SYNC OR ASYNC
LINE INTERFACE
Interface: Standard registered RJ-48s jack on the rear panel.
RX Levels: Supports at least 40 db attenuation (exceeds Telco requirements by 6 db).
Equalization: Automatic, no user adjustment needed.

BAT VRL-1 Specifications

GENERAL
Line Rate: 56K, 19.2K, 9.6K auto adaptive
Operating Modes: Dataphone Digital Service (DDS) in point to point or multi-point applications.
May also be used as Limited Distance Modem.
Standard Features: Slave and master timing.
Async operation.
Integral diagnostics.
Adaptable terminal side rates.
Both RS-232 and V.35 connectors and interfaces provided.
Test Features: Ten front panel status and test indicators. Front panel push button selects the following test modes: Self Test, Digital Loop, Local Loop, Remote Loop.
Responds to Bell defined CSU and DSU loop backs from the Central Office.
Internal test pattern generator.
AC Power: 117 VAC +/- 10%, 60 Hz, 12w
Environment: 0 to 50 C, up to 95% humidity.
Physical: Height..............2.50 In.
Width...............8.00 In.
Depth...............6.25 In.
CUSTOMER INTERFACE
Connectors: Both V.35 and RS-232 connectors and interfaces provided.
Operating Modes:
Mode 1: Telco Line Speed 56K
Terminal Config.: Speed Interface Sync Async
56.0K V.35 YES NO
38.4K RS-232 YES YES
19.2K RS-232 YES YES
9.6K RS-232 YES YES
4.8K RS-232 YES YES
2.4K RS-232 YES YES
1.2K RS-232 YES YES
MODE 2: Telco Line Speed 19.2K
Terminal Config.: 19.2K RS-232 YES YES
MODE 3 Telco Line Speed 9.6K
Terminal Config.: 9.6K RS-232 YES YES
Data Format: Synchronous or Asynchronous (7/8 data bits one stop bit)
LINE INTERFACE
Interface: Standard registered RJ-48s jack on the rear panel.
RX Levels: Supports 40 db attenuation (exceeds requirements by 6 db).
Equalization: Automatic, no user adjustment needed.

BAT SPEAK EZ-2 Specifications

CUSTOMER
DATA INTERFACES: Both V.35 and RS-232 connectors and interfaces are provided.
VOICE INTERFACES: Three separate voice interfaces and jacks are provided.
The SPEAK EZ-2 can accommodate a telephone, PBX tie trunk, or a PBX extension line.

All of the necessary couplers are provided and are internal to the device.

FAX SIGNALING: The SPEAK EZ-2 supports FAX through its voice port.
SIGNALING: Audible remote ringing and dial tone and touch tone propagation. Integral ringer provided.
CONFIGURATIONS: VOICE SPEED DATA SPEED
16K 38.4K OR 19.2K
32K 19.2K OR 9.6K
REAR PANEL: The rear panel contains the following:
3] Voice Jacks 1] V.35 Connector
1] RS-232 Connector 1] DIP to set options
1] Telephone line connection 1] Power connection
CSU / DSU
LINE RATE: 56K BPS
LINE INTERFACE: Standard DDS service. Supports up to 48db of attenuaton.
FEATURES: Internal external timing, permanent RTS.
TEST FEATURES: Supports CSU/DSU loop as well as standard BAT remote test features.
Front panel selector enables the test capabilities including local loop and digital loop.
Internal test pattern generator supplied.
GENERAL
AC POWER: 117 VAC +/- 10%, 60 HZ, 30 WATTS
POWER ISOLATION: Terminal equipment interfaces operate from their own isolated power. This eliminates telephone to computer system ground loops.
ENVIRONMENT: 0 to 50 C, up to 95% humidity.
PACKAGING: Table top enclosure, with rack mount capability.

BAT ELECTRONICS CSU/DSU PRODUCT FEATURES

DDS SP VRT-4 VRT-2 VRT-1 VRL-1 SU5696 SU56K+ SU56K SU64K+ VRT-1/64K
64.0K . . . . . . . X X
56.0K X X X X X X X . .
19.2K . . . X X . . . .
9.6K . . . X X . . . .
 
AUTO SP . . . X X . . . .
 
DTE SP
64.0K . . . . . . . X X
57.6K . . . . . . . . X
56.0K . X X X X X X . .
38.4K X X X X . . . . X
19.2K X X X X X . . . X
9.6K X X X X X . . . X
4.8K . X X X . . . . .
2.4K . X X X . . . . .
1.2K . X X X . . . . .
 
RATE ADAPT X X X X . . . . X
 
SYNC X X X X X X X X X
ASYNC X X X X X . . . X
 
RS-232 X X X X X X . X X
V.35 X X X X X X X X X
 
INTERN MUX 4CH 2CH . . . . . . .
 
AUTO EQUAL X X X X X X X X X
 
DIAG                  
DIG LOOP X X X X X X X X X
SELF TST X X X X X X X X X
LINE LP X X X X X X X X X
PAT GEN X X X X X X X X X
TELCO X X X X X X X X X
REMOTE X X X X X X X X X
I/O LED'S X X X X X X X X X
TST LEDS X X X X X X X X X
 
LIFETIME WARN'TY X X X X X X X X X
 
ADV SPARE X X X X X X X X X

Now available with a power input option of 12, 24 or 48 VDC. The input floats so ground loops are eliminated. The input total power requirement is under 3.5 watts. Power input can be from solar cells or regular battery. Wide voltage swings can be tolerated - temperature range of -30 to +150 degrees Fahrenheit - power input option of 12, 24 or 48 VDC -

jump to VRT-1 CSU/DSU
jump to VRL-1 CSU/DSU


ARC ELECTRONICS
301-924-7400 EXT 25 / 301-924-7400 EXT 25 / fax 301-924-7403

jump to ... Home Page

arc@arcelect.com