Rhino Channel Bank Specifications |
Rhino
Channel Banks
A Rhino channel
bank offers several solutions for T1 connectivity. Rhino channel banks are
feature rich and are specifically designed for ease of use and
maintenance.
Every Rhino
channel bank will configure itself to the T1 when plugged in and powered
up. Also standard with each Rhino Channel bank is a 4 line by 40-character
LCD display. This display in conjunction with the four menu buttons can be
used to manually configure your channel bank if your installation calls
for a more specific needs. I A Rhino channel banks feature a single CSU (for free) that is software controlled, software programmed and will self boot to the proper mode right out of the box. Now, with our
new modular channel bank, you can custom build a Rhino channel bank to
your exact specifications. Don’t need a full 24 line channel bank? No
problem. Build your channel bank in four channel increments. Need to
combine FXS and FXO lines into one channel bank? Again, not a problem. You
can mix and match FXS and FXO cards also in four line increments into one
Rhino chassis. |
Features for the Rhino channel bank
T1 CSU
All Rhino channel banks feature a single CSU that is software controlled,
software programmed and will self boot to the proper mode right out of the box.
T1 Channel
Bank Specifications
|
Rhino Models
•CB24-FXS-110V - T1, 24 FXS analog channels, 110VAC
•CB24-FXS-220V - T1, 24 FXS analog channels, 220VAC
•CB24-FXS--48V - T1, 24 FXS analog channels, -48VDC
•CB24-FXO-110V - T1, 24 FXS analog channels, 110VAC
•CB24-FXO-220V - T1, 24 FXS analog channels, 220VAC
•CB24-FXO--48V - T1, 24 FXS analog channels, -48VDC
•CB24-MOD-110V - T1, 4-24 FXS/FXO analog channels, 110VAC
•CB24-MOD-220V - T1, 4-24 FXS/FXO analog channels, 220VAC
•CB24-MOD--48V - T1, 4-24 FXS/FXO analog channels, -48VDC
FXS port conigurations |
4 Channels |
8 Channels |
12 Channels |
16 Channels |
20 Channels |
24 Channels |
FXO port conigurations |
4 Channels |
8 Channels |
12 Channels |
16 Channels |
20 Channels |
24 Channels |
Mixed Mode ports conigurations |
4 FXS, 4 FXO channels |
4 FXS, 8 FXO channels |
4 FXS, 12 FXO channels |
4 FXS, 16 FXO channels |
4 FXS, 20 FXO channels |
8 FXS, 4 FXO channels |
8 FXS, 8 FXO channels |
8 FXS, 12 FXO channels |
8 FXS, 16 FXO channels |
12 FXS, 4 FXO channels |
12 FXS, 8 FXO channels |
12 FXS, 12 FXO channels |
16 FXS, 4 FXO channels |
16 FXS, 8 FXO channels |
20 FXS, 4 FXO channels |
Modular Build Assignments |
Channels 1-4 5-8 9-12 13-16 |
The modular Rhino channel banks can be ordered with four to 24 channels of
either FXS or FXO analog channels installed, in increments of four channels, up
to six modules.
All Rhino channel banks come in 110VAC, 220VAC or -48V DC models, The internal
power supply module can easily be swapped.
see Rhino page see manual PDF
ARC ELECTRONICS
jump to ...
Home
Page
arc@arcelect.com