R3 Rack Mount Card Cage |
Fiber modem Rack mount card
cage with built-in power supply
for the IFS fiber optic units
R3 19” Rack, 115 VAC Input (includes power supply) |
The design approach employed by IFS for equipment mounted within
the model R3 Chassis Rack Unit with Integral 115/230 VAC Power Supply, provides
for the elimination of a single-point failure in the event of a major fault
within any module located within the chassis rack. This is accomplished through
the use of automatic electronic current limiting within each rack-mountable
module, rather than to provide the current limiting within the power supply unit
which supports the power requirements for equipment located within the rack. In
nearly all competing designs, a major fault within a module, located within the
chassis rack, results in the power supply unit going into a current limiting
condition, and as a result, all of the modules located within the rack shut
down. The R3 Rack design employed by IFS eliminates this possibility, as only
the faulty module shuts down, and the operation of the other devices within the
rack continues unimpaired. This automatic current limiting feature is also
self-resetting, should the fault or overload be of a temporary or intermittent
condition. Furthermore, all modules located within the chassis rack are
hot-swappable, so that it is not necessary to power-down the rack when removing
or replacing modules. Rather than utilizing a switching-mode or linear DC
power supply for providing the operating power to the rack as employed by most
competing designs, the IFS Model R3 Chassis Rack uses a simple under stressed
step-down power transformer, and all rectification, filtering, and regulation is
performed within each rack mounted module. The use of a step-down power
transformer for the power supply unit results in a significantly higher MTBF
than any switching-mode or linear DC power supply can provide, as there are no
semiconductors, electrolytic capacitors, etc., to degrade the reliability of the
supply. In addition, the high-reliability transformer power supply and current
limiting built into each module, eliminates the necessity of providing redundant
power supplies within the chassis rack, as the overall system reliability is
still much higher (and less costly) than can be provided with a redundant power
supply design approach.
part numbers to order under
R3 19” Rack, 115 VAC Input (includes power supply)
R3-DC-115 19” Rack, 115 VAC Input (DC Back Plane included)
R3-230 19” Rack, 230 VAC Input (includes power supply)
R3-CH 19” Rack, No power supply
R3-BP Blank Panel (1”)
PS-R3 115 VAC Power Supply
PS-R3-24 24 VDC Power Supply
PS-R3-48 48 VDC Power Supply
PS-R3-230 230 VAC Power Supply
see PDF