| Input |
| Voltage range |
100-240VAC |
| Frequency |
50/60Hz |
| Input current |
0.3A(rms) for 115VAC, 0.2A (rms) for
230VAC. |
| Safety gad leakage current |
0.25mA max @ 240VAC 50Hz. |
| Insulation resistance
|
50MOhm min from output to
ground. |
| Inrush current |
15A @ 115VAC, or 30A @ 230vac
at 25°C cold start.
|
| Output |
| Voltage |
24VDC |
| Output current |
0.25A |
| Ripple |
±1% p-p max. |
| Over voltage protection |
Yes (clamp by Zener diode).
|
| Over current protection |
Yes
(for primary-referenced direct driver, constant current series
for secondary-referenced direct drive). |
| Temperature coefficient |
All outputs ±0.04%/°C max. |
| Transient response |
Max excursion of 4% or better on all
models,
recovering to 1% of final value 500uS after a 25% step load
change.
|
| Efficiency |
65% min at full output. |
| Hold-up time |
5msec min. |
| Line regulation |
±1% max for input voltage change
between input voltage range. |
| Load regulation |
±5% variations from min to max
output current.
|
| General |
| MTBF |
50,000 hours min at full load at 25°C ambient.
|
| Environmental |
| Operating Temperature |
0 °C to +40°C |
| Storage Temperature |
-40 °C to +85°C |
| Humidity |
5 to 95%, Non-condensing |
| Derating |
Derated from 100% at +40 °C linearly
to 50% at 70 °C.
|
| Standards |
| Safety standards |
Meets or exceeds UL1950,CSA
C22.2, TUV EN60950, IEC950. |
| EMI |
Meets conduction limits of FCC
Part 15 Class B, CISPR 22.2 |