Star-Comm Low Power Modems |
Low power for solar power
applications
SCADA Communications Solutions for Utility
and Industrial Automation applications
Low power for solar power applications V.34, V.32bis, V32, V.22bis, V.22, V23, V.21, BELL 212A, 103J - DC power 9-72 VDC or AC
DIAL and Lease Line MODEM
IDEAL FOR USE IN: |
|
IDEAL FOR USE IN:
|
There are a growing number of remote
communications applications where power consumption is a major issue. Often, these
environments are solar powered and require that equipment operate over a wide voltage
range. The StarComm 1442L and 33421L are designed to address these specific requirements.
Since all StarComm communications products are designed to withstand the rigors of
industrial use, you can expect years of trouble free operation from the 1442L and 3342L.
From traffic monitoring applications, in the heat of the Arizona desert to weather
surveillance installations in Alaska, StarComm. has developed a reputation for
performance, quality and unique feature sets:
AUTOMATIC POWER UP ON RING DETECT - StarComm Low Power Modems remain in a low power standby mode until an incoming call presents a ring signal to the device. When the ring signals detected the device powers on and accepts the call. After the call has completed, the device will return to a low power standby mode.
EXTERNAL POWER SEQUENCING ON RING DETECT - All models provide relay contacts for sequencing power to other devices. The relay is activated after the first ring cycle and deactivated when the modem returns to low power standby mode.
FLEXIBLE POWER SUPPLY OPTIONS - All models offer power options to meet a wide range of AC and DC requirements.
F
LEXIBLE PACKAGE OPTIONS - All models are available in our standard stand alone or rack mount configurations. In addition, all models are available at the board level for OEM applications.COMPATIBLE WITH ALL STANDARD MODEMS
ENGINEERED AND MANUFACTURED TO COMMERCIAL STANDARDS
these part numbers have been replaced by the - 3342E-208-4
1442L and 3342L Low Power Standby Modems All models offer an AT compatible command interface and support the following modulation standards: V.34(3342 only), V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A and Bell 103J. These models are designed to enter a low power standby state when there is no activity. Standby current is approximately 5ma.
1442E-008-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
1442E-208-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
1442E-308-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc
3342E-008-2 Stand alone, for 2-wire dial circuits. Power: 9vac or 9-14vdc
3342E-208-2 Stand alone, for 2-wire dial circuits. Power: 5.5-14vdc
3342E-308-2 Stand alone, for 2-wire dial circuits. Power: 18-75vdc
FEATURES AND SPECIFICATIONS
COMPATIBILITY (3342L) -V.34, V.32bis, V32, V.22bis, V.22, V23, V.21, BELL 212A,
BELL 103J.
COMPATIBILITY
(1442L) - V.32bis, V.32,1422bis, 1422, V13, V21, BELL
212A, BELL 103J.
DTE INTERFACE (3342L) - RS-232C (V.24). Autobaud or fixed data rates to 11 5.2Kbps.
DTE INTERFACE (1442L) - RS-232C (V.24). Autobaud or fixed data rates to 57.6Kbps.
AUTO DIAL MODES - Standard AT compatible dial commands or DTR dial of stored number.
ANSWER MODES - Standard auto answer or manual answer under DTE control.
ERROR CORRECTION - V.42 and MNP 2-4 error correction. MNP 10 extended cellular services.
DATA COMPRESSION - V.42bis and MNP5 data compression.
CONFIGURATION CONTROL - Standard AT commands.
DIAGNOSTICS - V.54 through AT commands.
LINE INTERFACE - 2 wire, pulse or DTMF dial. XMT level: - 12dBm, RCV
sensitivity: -43dBm.
POWER (STAND ALONE UNITS) - Standard wide range DC supply operates from 5.5-14VDC.
Optional supply automatically adjusts to 9VAC or 9-14VDC. Current consumption in low power
standby mode: about 5ma. Operating current at 12VDC : 260ma.
POWER (RACK MOUNT) - Standard CC-2016 rack automatically adjusts to 85-265VAC, 27-44OHz. Optional DC supply automatically adjusts to positive or negative 36-75VDC.
ENVIRONMENTAL - Operating temperature range:
-20C(-40F) to
+70C(+160F) C. Humidity: 90% non-condensing - (optional -20C to +80C available
soon).
APPROVALS - Standard: FCC Part 68 & Part 15, Class A.
Optional: International approvals available.
PHYSICAL (STAND ALONE UNITS) - Dimensions: 5.30"L x
5.05"W x 1.53"H. Weight: l2oz.
PHYSICAL (RACK MOUNT) - Fits standard CC-2016 rack. 4.73"L x
4.60"W x.80"H. Weight: 9oz.
Options
RACKS - The CC-2016-XX Series of 16 Slot Rack Mount Enclosures
These enclosures provide 16 modem slots in a standard 19 inch form factor which is 5 inches high and 6.5 inches in depth. The standard power system auto ranges from 85 to 265VAC with a frequency range of 27 - 440hz. An optional DC supply is also available for installations requiring operation on 36 - 75VDC. All rack configurations are designed for operation from -20C to +70C and offer a mean time between failure (MTBF) of 200,000 hours (22.8) years.
BRACKET - 19 Inch Rack Mount Bracket For All Stand Alone Models
This bracket provides mounting for three 5"x 5"stand alone modems or two 5 by 7" multi-port modems within a standard 19 inch rack.
BRACKET - 9 Inch Wall Mount Bracket For All Stand Alone Models
visit our other Star-Comm modem pages
jump to Star-Comm
main page
jump to Low
Power Manual PDF
file
jump to
DC
power connections diagram
(NOTE power plug polarity -
center pin is positive and the out side of 5.5 barrel connector is negative)
ARC ELECTRONICS
Phone us at - 301-924-7400 EXT 25
e-mail Sales at arc@arcelect.com