CDMA Digital Cellular Modem 1xRTT -

Tri-Mode Multi-Mode data modem


CDS-9022 (now called the 9022"A") CDMA cellular modem - Analog Tri-mode Modem, RS232, SMS, analog data capability. Cellular modem at  800 MHz & 1900 MHz for Sprint and Verizon


the CDS-9022 tri-mode dual frequency 820-850 and 1.9Ghz
part Number has changed to the DCS-9022A

  • Authentication (CDMA)
  • Authentication analog AMPS cellular
  • Preferred Roaming List
  • IS-707A service SMS commands
  • SMS via AT-Commands
  • TCP/PPP
  • Update PRL while unit is in the field
  • DRI Configuration menu remotely or locally programmable
  • Inputs for cry-out alarms
  • Analog Modem MNP-10EC and X-Cel error correction, V.22 to V.32Bis
  • Upgradeable to CDMA 1X technology when available
  • Switches from CDMA mode to analog automatically
  • Tri-mode call processing: AMPS 800MHz, CDMA digital 800MHz, and CDMA PCS 1900 MHz
  • Voice Communications

jump to CDS-9022 Manual

SMS ADDENDUM FOR THE CDS-902X AND CDS-905X SERIES CELLULAR MODEMS


Specifications

Power Requirements: 10.5-20VDC @ 1A (unregulated)
On-Board Backup: 3.6V 200MA (CR2032) Lithium Cell
Serial I/O: RS-232, Async, 2 DB-9 and 1 - 8 pos. terminal block Connectors
Control I/O: 12 Pos. IDC compatible header
Command Protocol: AT Command Set and DataRemote, Inc (DRI) Configuration Menu
LED Indicators: Power ON, Status, TXD, RXD, DCD, DTR
Ear/Mic Connector: 2.5 mm stereo type jack
Modem: IS-707A compatible, IS-95A/B (MDR verified on IS-95A/B networks)
AMPS modem (Conexant Chipset)
Vocorder: 8 Kbps CELP, 13 Kbps QCELP, 8 Kbps EVRC
FCC ID: QVFQCP-2035
Canada ID: 3572291146

RF SPECS

800 MHz 1900 MHz
Interface Standards: AMPS: ANSI/TIA/EAI-553
CDMA: TIA/EIA, IS-95A/B
J-STD-008
Operating Frequencies: TX: 824-849 MHz
RX: 869-894 MHz
TX: 1850-1910 MHz
RX: 1930-1990 MHz
RF Power: AMPS: 600mW (EIRP Nom.)
CDMA: 200mW (EIRP Nom.)
200mW (EIRP Nom.)
Maximum TX Power: AMPS: +26.7dBm Min.
CDMA: +23dBm Min.
+23dBm Min.
Receiver Sensitivity: AMPS: >116dBm @ 12dB Sinad
CDMA: >-104dBm @ 0.5% FER
>-104 dBm @ .05% FER
Frequency Stability: < ± 2.5 PPM < ± 2.5 PPM
Antenna Interface: 50 ohm, TNC 50 ohm, TNC
Size: 6.5"L X 3.7"W X 2.5" H
Weight: 24.0 Oz.
Temperature: Operating: -30° C to +60° C
Storage: -40° C to +70° C
Humidity: 0-95% (non-condensing)
OPTIONS
  • Headset with volume control
  • Hands-free external speaker and microphone
  • Custom scripts for ProComm+® for remote access
  • Remote equipment sensing and control
APPLICATIONS
  • Automatic meter reading
  • Security system monitoring via RS-232
  • Slow-speed video applications
  • Heavy equipment monitoring
  • Traffic metering and programming highway displays
  • Connects to RTU’s, PLC’s, Data loggers, etc. through a DTE RS-232/485 port
  • Flood control monitoring
  • Remote equipment sensing and control
  • Pre-programmed emergency calls to 911 or dispatcher

CELLULAR MODEMS

Product No.

Description

CDS-9020 CDMA Data Modem, RS232 and SMS capability, 800 and 1900MHz, NO Analog capability
CDS-9022 CDMA/Analog Tri-mode Modem, RS232, SMS, analog data capability, including handsfree voice, 800 & 1900 MHz
CDS-9030 Low Cost CDMA/PCS RS-232 Wireless Data Modem with AMPS analog add-on feature
CDS-9050 CDMA Data Modem, with GPS engine, 512 Kb memory (upgradable to 1Mb), dual DCE RS232 I/O ports, SMS, user configrable I/O control features for remote equipment, configurable internal data logging, 800 and 1900 MHz
CDS-9052 CDMA/Analog Tri-mode Modem, with GPS engine, handsfree voice, analog data capability, 512 Kb memory (upgradable to 1Mb), dual DCE RS232 I/O ports, SMS, user configrable I/O control features for remote equipment, configurable internal data logging, 800 and 1900 MHz
CDS-9060 CDMA2000 1xRTT Data Modem, with GPS engine, 512 Kb memory, dual DCE RS232 I/O ports, SMS, user configurable I/O control features for remote equipment, configurable internal data logging, 800 and 1900 MHz  Analog Modem Upgradeable (CDS-9060A)
CDS-9060TR

Access data with an RJ-11 modem output. It's perfect for legacy equipment. Wireless Modem for RJ11 Devices to Transmit Data via Digital Cellular

Note: Power supplies, antennas and NEMA enclosures are not included with modems unless otherwise ordered. All DataRemote modems are supplied with a User Guide, test antenna, RS-232 interface cable and terminal software for initial setup and testing. Click here for approved alternative antennas.


jump to cellular antenna installation guidelines
jump to
cellular Yagi high gain antenna
jump to Mobil antennas

Digital Coverage map as of 2003 JPG
Digital Coverage map as of 2003 PDF

new Verzion 1xRTT rate plan
Verizon Wireless Packet Data Rates


 

 Jump to Cellular Digital coverage map

   Jump to CDPD coverage map   

  Jump to AMPS and Digital  coverage map

   Jump to PDF file on 3G 

   Jump to 2G-3G Cellular Wireless 
        
data transport terminology

  Jump to What is CDMA

   Jump to CDMA Wireless Academy 

  Jump to What is MNP-10EC 

  Jump to What is Throughput X-Cellerator TX-Cel 

  Jump to Cellular news 


call 301-924-7400 EXT 25
 or e-mail sales
sales@data-connect.com

ARC ELECTRONICS
a DCE Company

jump to ... Home Page