Telenetics MIU modem / AC & DC power
The Telenetics MIU2.4/MIU2.4LV MODEM
HARDENED and INDUSTRIAL GRADE

  • Telenetics MIU2.4 modem 48VAC/DC to 220VAC/DC

  • Telenetics MIU2.4LV modem 9 to 36VDC (DC only)   

  • .3/1.2/2.4/kbps

  • 5VDC to 220VAC/VDC Power Supply

  • IEC801-4/5 Surge Protection

  • -40oC to +85oC Operating Temp.

  • RTU, Meters, Relays, SCADA

Telenetics has designed modems that work in "remote" remote sites with very low failure rates. These devices work where other modems roll over and die. When a service call to a remote site can mean an all day trip these modems are the ideal solution.

To service the growing need for efficient, reliable data communications in the harsh environments of "remote" remote sites and industrial facilities. Telenetics has developed a family of data communications products that can operate from various AC & DC power supplies and survive high surge levels and extreme heat and cold. All this without compromising the performance expected from state-of-the-art communications devices.

 

Telenetics MIU24 Modem

   Data Rate (bps)
   Standard
     48 - 240V AC or DC
9 - 36V DC +5V and 12 VDC
2400 V.22bis MIU2.4 MIU2.4-LV MIU / Power Port 2.4

 

MIU24

MIU96FP

MIU144

 

 

 

 

 

 

 

 

Modem Line Speeds:
Asynchronous

2400, 1200,
300bps

4800, 9600,
14400bps

14400, 9600,
4800, 2400,
1200, 300bps

 

 

 

 

DTE Rates: above modem line speeds (ie; with data compression)

none

4800, 9600,
14400bps

57.6, 38.4,
19.2kbps

 

 

 

 

 

 

 

 

 

 

 

 

Standards:

Bell 212A
V.22bis, V.22
Bell 103

V.27 & V.29

V.32bis, V.32
V.22bis, V.22
Bell 212A,Bell 103

 

 

 

 

Dial Up

MIU2.4

 

MIU14.4

 

 

 

 

2 & 4-Wire Leased Line

No

MIU9.6FP

MIU14.4L

 

 

 

 

       
Compatibility Hayesª Extended AT Command Set None Hayesª Extended AT
 Command Set
       
Error Correction / Data Compression None None MNP 2, 4, 5 & 10
V.42, V.42bis
       
Power Supply 48VAC/DC to 220VAC/DC "LV" - Optional 9-36VDC
       
Power Connector 4-ft AC Cord with 3-Pin Screw Terminal connector included
       
Case Size   5-3/8" x 4" x 1-3/8"
       
Digital Port   RS232 with FEM DB9 Connector
       
Analog Port   RJ-11 Modular Jack
     
Surge Protection
(Power Line)
  8kV [Exceeds IEC801-4]
(20kV [IE801-5] available if required)
   
Surge Protection
(Analog Line)
5kVac 3.75VAC 3.75kVac
       
Environment -40¡C to +85¡C, 0 to 95% humidity (non-condensing)
       
Certifications FCC Part 68, Industry Canada FCC Part 68, Industry Canada
 

jump to other MIU modems
jump to related Telenetics pages


ARC ELECTRONICS
301-924-7400 EXT 25

jump to ... Home Page

arc@arcelect.com